Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/10939
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Lozada Yánez, Raúl Marcelo | - |
dc.contributor.author | Lesano Muñoz, Amanda Karina | - |
dc.date.accessioned | 2019-06-25T17:01:15Z | - |
dc.date.available | 2019-06-25T17:01:15Z | - |
dc.date.issued | 2018-12 | - |
dc.identifier.citation | Lesano Muñoz, Amanda Karina. (2018). Implementación y evaluación de dos prototipos basados en tecnologías inalámbricas para la adquisición y procesamiento de señales cardiacas en tiempo real. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/10939 | - |
dc.description | Este trabajo de titulación tuvo como objetivo la implementación y evaluación de dos prototipos para la adquisición de señales cardiacas en tiempo real, el primer prototipo está basado en la tecnología Wifi y el segundo en Bluetooth. El prototipo está formado por 5 bloques que son: sensorial, procesamiento, comunicación, almacenamiento y visualización. Para el bloque sensorial se ha analizado la mejor técnica para la adquisición del pulso cardiaco mediante bibliografía especializada. El procesamiento en el prototipo wifi se realiza mediante la tarjeta MCU ESP 8266 y en el prototipo Bluetooth se realiza mediante la tarjeta de desarrollo Arduino nano. La comunicación para el prototipo Bluetooth será a través del módulo HC-06 y para el prototipo Wifi a través de la tarjeta MCU ESP 8266. El almacenamiento será en una tarjeta micro SD. La visualización en el prototipo Bluetooth se realiza mediante una aplicación para Android y en el prototipo Wifi a través de una red inalámbrica. Mediante la utilización de la consola de comandos de Windows para la tecnología wifi y para la tecnología Bluetooth se desarrolló un programa en el software Arduino IDE que trabaja como un sniffer para determinar la cantidad de paquetes recibidos y enviados, con su respectivo tiempo de retardos, posteriormente con estos datos se analizó factores de rendimiento como: Throughput, perdida de paquetes, promedio de retardos, relación de la entrega. El análisis se realizó con 30 muestras por cada tecnología, tomando en consideración que se envió un total de 100 paquetes de datos por muestra, los resultados obtenidos determinaron que la tecnología Wifi es superior en un 71% con respecto a la tecnología Bluetooth generando mejores prestaciones, por lo que se recomienda para tener un buen resultado de los datos el mismo número de muestras para las dos tecnologías para su posterior análisis. | es_ES |
dc.description.abstract | The aim of the present research work was to implementation and evaluation of two prototypes for the acquisition of real time cardiac signals, the first monitor uses Wi-Fi technology and the latter Bluetooth. The prototype consists of 5 blocks: sensorial, processing, communication, storage and visualization. For the sensorial block, a review of specialized literature allowed to identify the best technique for the acquisition of cardiac pulse. The Wi-Fi device uses an MCU ESP 8266 processing card and the Bluetooth device uses an Arduino Nano development card. The communication for the Bluetooth device will be performed through the HC-06 module and for the Wi-Fi device through the MCU ESP 8266 card. For data storage, a micro SD card will be used. The visualization in the Bluetooth device is carried out through an Android application and in the Wi-Fi device through a wireless network. For both, the Wi-Fi technology and the Bluetooth technology, using the Windows command console, a program was developed in Arduino IDE which works as a sniffer to determine the amount of sent and received packs, with their corresponding delay times. Then, using these data, different performance factors such as: Throughput, package loss, delay average, delivery relationship. The analysis was performed using 30 samples for each technology, considering that a total of 100 data packages per sample. The results show that Wi-Fi technology is 71% superior to Bluetooth generating better benefits. To obtain a better result from the data, it is recommended to collect the same number of samples for both technologies for analysis. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;98T00229 | - |
dc.subject | TELECOMUNICACIONES | es_ES |
dc.subject | CIENCIAS MÉDICAS | es_ES |
dc.subject | DISPOSITIVOS MÉDICOS | es_ES |
dc.subject | SENSOR DE RITMO CARDÍACO | es_ES |
dc.subject | ADQUISICIÓN DE DATOS | es_ES |
dc.subject | RITMO CARDÍACO | es_ES |
dc.title | Implementación y evaluación de dos prototipos basados en tecnologías inalámbricas para la adquisición y procesamiento de señales cardiacas en tiempo real. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Martínez Guashima, Oswaldo Geovanny | - |
Aparece en las colecciones: | Ingeniero en Electrónica, Telecomunicaciones y Redes; Ingeniero/a en Telecomunicaciones |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
98T00229.pdf | 2,42 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.