Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/10538
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | León Chimbolema, José Gerardo | - |
dc.contributor.author | Torres Aveiga, Génesis Fiorella | - |
dc.date.accessioned | 2019-04-30T22:55:04Z | - |
dc.date.available | 2019-04-30T22:55:04Z | - |
dc.date.issued | 2018-08 | - |
dc.identifier.citation | Torres Aveiga, Génesis Fiorella. (2018). Rediseño de la planta de tratamiento de lixiviados del complejo ambiental para la disposición final de residuos sólidos del cantón Santo Domingo. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/10538 | - |
dc.description | El objetivo fue el rediseño de la planta de tratamiento de lixiviados del Complejo Ambiental para la Disposición Final de Residuos Sólidos del Cantón Santo Domingo, siendo los lixiviados líquidos muy complejos y altamente contaminados aumenta la preocupación por el bienestar de la población, el cuidado ambiental, el desarrollo del cantón y el tratamiento impartido, motivo por el cual se planteó el rediseño basándose en la revisión analítica de literatura y recopilación de datos técnicos por medio de la verificación in situ del diseño y funcionamiento de la planta, se estimó la generación de caudal por medio del método volumétrico en base a la diferenciación de alturas, se utilizó la caracterización de lixiviados para determinar la eficiencia de la planta de tratamiento basándose en el porcentaje de remoción de Demanda Bioquímica de Oxígeno (DBO5), Demanda Química de Oxígeno (DQO) y Turbiedad, se realizó una prueba de tratabilidad basada en la prueba de jarras con una dosificación de floculante 4 ml, policloruro de aluminio 8 ml, cloruro férrico 8 ml , agitación de 1 minuto a 100 rpm y 3 minutos a 50 rpm métodos por los cuales se obtuvo como resultado que la planta se encuentra mal operada y que se produce 26 m3/día de lixiviado que no es tratado por ninguna etapa por lo cual se diseñó un humedal artificial vertical subsuperficial con un área superficial de 45.662 m2, un tiempo de retención de 0.354 días, ancho de 0.56 m, largo de 81.54 m y una cantidad de medio filtrante de arena gruesa 15.981 m3, arena gravosa 5.479 m3, arena grava media 4.566 m3. Concluyendo que se necesita del rediseño y optimización de todas las fases de tratamiento implementadas en la planta para lo cual se recomienda dar énfasis a los procesos de operación y realizar el mantenimiento de las instalaciones. | es_ES |
dc.description.abstract | The objective was the redesign of the environmental complex for the final disposal of solid waste’s leachate treatment plant of Santo Domingo canton, being the leached liquids very complex and highly contaminated it increases the concern about the population’s welfare , the environmental care, the canton’s development and the treatment given, were the reason why the redesign was proposed based on the literature analytical review and collection of technical data through the in situ design and plant operation verification, the flow generation was estimated by the volumetric method based on heights differentiation, the characterization of leachates was used to determine the treatment plant efficiency based on the biochemical oxygen demand removal percentage (BOD5), oxygen chemical demand (COD) and turbidity, a treatability test was carried out based on the jar test with a flocculants dosification 4 mL, aluminum polychloride 8 mL, agitation of 1 minute at 100 rpm and 3 minute at 50 rpm, through the use of these methods we found as a result that the plant is badly operate and it produces 26 m3 leachate a day that is not treated in any stage whereby a vertical artificial subsurface wetland was designed with a surface area of 45,662 m2, a retention time of 0,354 days, width of 0,56 m, length of 81.54 m and an amount of medium sand filtering 15,981 m3, sand gravel 5,479 m3, medium gravel sand 4,566 m3. Concluding that it is necessary to redesign and optimize all the treatment phases implemented in the plant, it is recommended to give emphasis to give emphasis to the operational processes and give the facility’s maintenance. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;236T0397 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | BIOTECNOLOGÍA | es_ES |
dc.subject | INGENIERÍA Y TECNOLOGÍA SANITARIA | es_ES |
dc.subject | REDISEÑO DE LA PLANTA DE TRATAMIENTO | es_ES |
dc.subject | TRATAMIENTO DE LIXIADOS | es_ES |
dc.subject | IMPACTO AMBIENTAL | es_ES |
dc.subject | CONTAMINACIÓN AMBIENTAL | es_ES |
dc.subject | SANTO DOMINGO (CANTÓN) | es_ES |
dc.title | Rediseño de la planta de tratamiento de lixiviados del complejo ambiental para la disposición final de residuos sólidos del cantón Santo Domingo. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Santillán Quiroga, Miguel | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
236T0397.pdf | 2,61 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons